Showing posts with label 555. Show all posts
Showing posts with label 555. Show all posts

Monday, September 1, 2014

Nine independent telephones (using a single telephone line pair)

This circuit is able to handle nine independent telephones (using a single telephone line pair) located at nine different locations, say, up to a distance of 100m from each other, for receiving and making outgoing calls, while maintaining conversation secrecy. This circuit is useful when a single telephone line is to be shared by more members residing in different rooms/apartments. Normally, if one connects nine phones in parallel, ring signals are heard in all the nine telephones (it is also possible that the phones will not work due to higher load), and out of nine persons eight will find that the call is not for them. Further, one can overhear others’ conversation, which is not desirable. To overcome these problems, the circuit given here proves beneficial,
as the ring is heard only in the desired extension, say, extension number ‘1’.
For making use of this facility, the calling subscriber is required to initially dial the normal phone number of the called subscriber. When the call is established, no ring-back tone is heard by the calling party. The calling subscriber has then to press the asterik (*) button on the telephone to activate the tone mode (if the phone normally works in dial mode) and dial extension number, say, ‘1’, within 10 seconds. (In case the calling subscriber fails to dial the required extension number within 10 seconds, the line will be disconnected automatically.) Also, if the dialed extension phone is not lifted within 10 seconds, the ring-back tone will cease.
The ring signal on the main phone line is detected by opto-coupler MCT- 2E (IC1), which in turn activates the 10-second ‘on timer’, formed by IC2 (555), and energises relay RL10 (6V, 100- ohm, 2 C/O). One of the ‘N/O’ contacts of the relay has been used to connect +6V rail to the processing circuitry and the other has been used to provide 220-ohm loop resistance to deenergise the ringer relay in telephone exchange, to cut off the ring.
When the caller dials the extension number (say, ‘1’) in tone mode, tone receiver CM8870 (IC3) outputs code ‘0001’, which is fed to the 4 bit BCD-to-10 line decimal decoder IC4 (CD4028). The output of IC4 at its output pin 14 (Q1) goes high and switches on the SCR (TH-1) and associated relay RL1. Relay RL1, in turn, connects, via its N/O contacts, the 50Hz extension ring signal, derived from the 230V AC mains, to the line of telephone ‘1’. This ring signal is available to telephone ‘1’ only, because half of the signal is blocked by diode D1 and DIAC1 (which do not conduct below 35 volts). As soon as phone ‘1’ is lifted, the ring current increases and voltage drop across R28 (220-ohm, 1/2W resistor) increases and operates opto-coupler IC5 (MCT-2E).
This in turn resets timer IC2 causing:
(a) interruption of the power supply for processing circuitry as well as the ring


Share:

Gas Leakage Alarm ( LPG gas leakage detector with audio visual indicator)

LPG gas is supplied in pressurized steel cylinders. As this gas is heavier than air, when it leaks from a cylinder it flows along floor and tends to settle in low spots such as a basement. This can cause fire or suffocation if not dealt with.

Here is a circuit that detects the leakage of LPG gas and alerts the user through audio-visual indications. Fig. 1 shows the circuit of the gas leakage alarm. The circuit operates off a 9V PP3 battery. Zener diode ZD1 is used to convert 9V into 5V DC to drive the gas sensor module. The SEN-1327 gas sensor module from RhydoLABZ is used in this circuit. Its output goes high when the gas level reaches or exceeds certain point. A preset in the module is used to set the threshold. Interfacing with the sensor module is done through a 4-pin SIP header. Pin details of the gas sensor module are shown in Fig. 2.


LPG Gas Leakage Alarm Schematic

An MQ-6 gas sensor is used in the gas sensor module. As per its datasheet, it has high sensitivity to propane, butane, isobutene, LPG and natural gas. The sensor can also be used to detect combustible gases, especially methane. This circuit has been tested with LPG gas and was found to work satisfactorily. Whenever there is LPG concentration of 1000ppm (parts per million) in the area, the OUT pin of the sensor module goes high. This signal drives timer IC 555, which is wired as an astable multivibrator. The multivibrator basically works as a tone generator. Output pin 3 of IC 555 is connected to LED1 and speaker-driver transistor SL100 through current-limiting resistors R5 and R4, respectively. LED1 glows and the alarmsounds to alert the user of gas leakage. The pitch of the tone can be changed by varying preset VR1. Use a suitable heat-sink for transistor SL100.
Share:

IR Remote Switch

Imagine the convenience of selecting TV channels using your remote and then pointing the same remote to your switchboard to switch on/off the fan or the tubelight. Here is a simple circuit to remotely switch on/off any electrical device through a relay using the normal TV/VCR/VCP/VCD remote controlunit. It works up to a distance of about 10 metres. The circuit is built around a 3-pin IR IC receiver (Siemens SFH-506-38 or equivalent) that can detect 38kHz burst frequency generated by a TV remote. (This IR receiver module has been covered earlier in many projects published in this blog.) The output pin of IR sensor goes low when it detects IR light, triggering the monostable (1-second) built around timer NE555. The output of the mono toggles the J-K flip flop, whose Q output drives the relay through SL100 npn transistor (T1).



LED2, LED3, and LED4 are used to display the status of each output stage during circuit operation. Back-EMF diode D5 is used for protection. Transistor T1 is configured as an open-collector output device to drive the relay rated at 12V DC. The circuit draws the power from voltage regulator 7805. Capacitor C5 is soldered close to the IR sensor’s pins to avoid noise and false triggering. Capacitor C3 and resistor R3 also avoid false triggering of monostable NE555. The monostable acts as a 1-second hysterisis unit to restrict the flip-flop from getting retriggered within one second. To activate any other 12V logic device, use the output across the relay coil terminals.
Share:

Touch Switch using 555 oscillator IC

This touch switch built based on famous 555 timer IC. When the plate is touched the 555 timer is triggered and the output on pin 3 goes high turning on the LED and the buzzer for a certain period of time. The time that the LED and the buzzer is on is based on the values of the capacitor and resistor connected to pin 6 & 7. The 10M resistor on pin 2 causes the the circuit to be very sensitive to the touch.